Practice Free HPE0-S59 Exam Online Questions
A customer is currently running a web server that is performing well. They now plan to add a new, memory-intensive database application to this same server.
Current Server State:
– CPU Utilization: 20%
– Memory Utilization: 30%
New Application Requirement:
– 128GB of dedicated RAM
What compute resource requirement has this change introduced?
- A . The server needs an additional 128GB of physical RAM.
- B . The server needs a storage array with higher IOPS.
- C . The server needs a faster network adapter.
- D . The server needs a CPU with a higher core count.
A customer is building an implementation plan to add 12 Large Form Factor (LFF) drives to an existing HPE ProLiant DL380 Gen10 server. The server’s chassis only holds 8 LFF drives.
Which component must be added to the implementation plan to support the additional drives?
- A . An HPE SAS Expander card.
- B . An external HPE Disk Enclosure (e.g., D3610) and an external SAS HBA.
- C . A redundant power supply.
- D . A second Smart Array controller.
A customer is building an implementation plan to add 12 Large Form Factor (LFF) drives to an existing HPE ProLiant DL380 Gen10 server. The server’s chassis only holds 8 LFF drives.
Which component must be added to the implementation plan to support the additional drives?
- A . An HPE SAS Expander card.
- B . An external HPE Disk Enclosure (e.g., D3610) and an external SAS HBA.
- C . A redundant power supply.
- D . A second Smart Array controller.
A customer is building an implementation plan to add 12 Large Form Factor (LFF) drives to an existing HPE ProLiant DL380 Gen10 server. The server’s chassis only holds 8 LFF drives.
Which component must be added to the implementation plan to support the additional drives?
- A . An HPE SAS Expander card.
- B . An external HPE Disk Enclosure (e.g., D3610) and an external SAS HBA.
- C . A redundant power supply.
- D . A second Smart Array controller.
An Implementation Specialist is verifying a BOM for a server that will connect to a new 10GbE SFP+ switch.
BOM:
– 1 x HPE ProLiant DL360 Gen10
– 1 x HPE Ethernet 10Gb 2-port 530T Adapter (RJ45)
Site Survey:
– Switch: 10GbE, 2 x SFP+ ports available
– Cabling: 2 x SFP+ DAC cables available
What incompatibility exists in this solution?
- A . The DL360 Gen10 does not support 10GbE speeds.
- B . The server requires a FlexibleLOM adapter, not a PCIe adapter.
- C . The server requires four network ports, but the adapter only has two.
- D . The 530T adapter (RJ45 ports) is not physically compatible with the SFP+ ports on the switch.
A Storage Administrator needs to modify an existing RAID 1 logical drive to a RAID 10 logical drive to improve performance. Both arrays use an even number of disks.
What is the correct method to perform this configuration change using Smart Storage Administrator (SSA) on a supported HPE Smart Array controller?
- A . Use the "Migrate RAID Level" function, as this is a supported online migration path.
- B . Add two new drives to the RAID 1 array and select the "Transform to RAID 10" option.
- C . Use the "Extend Logical Drive" function, as RAID 10 is an extension of RAID 1.
- D . Delete the RAID 1 logical drive (destroying all data) and create a new RAID 10 logical drive.
A Storage Administrator needs to modify an existing RAID 1 logical drive to a RAID 10 logical drive to improve performance. Both arrays use an even number of disks.
What is the correct method to perform this configuration change using Smart Storage Administrator (SSA) on a supported HPE Smart Array controller?
- A . Use the "Migrate RAID Level" function, as this is a supported online migration path.
- B . Add two new drives to the RAID 1 array and select the "Transform to RAID 10" option.
- C . Use the "Extend Logical Drive" function, as RAID 10 is an extension of RAID 1.
- D . Delete the RAID 1 logical drive (destroying all data) and create a new RAID 10 logical drive.
A Storage Administrator needs to modify an existing RAID 1 logical drive to a RAID 10 logical drive to improve performance. Both arrays use an even number of disks.
What is the correct method to perform this configuration change using Smart Storage Administrator (SSA) on a supported HPE Smart Array controller?
- A . Use the "Migrate RAID Level" function, as this is a supported online migration path.
- B . Add two new drives to the RAID 1 array and select the "Transform to RAID 10" option.
- C . Use the "Extend Logical Drive" function, as RAID 10 is an extension of RAID 1.
- D . Delete the RAID 1 logical drive (destroying all data) and create a new RAID 10 logical drive.
A Storage Administrator needs to modify an existing RAID 1 logical drive to a RAID 10 logical drive to improve performance. Both arrays use an even number of disks.
What is the correct method to perform this configuration change using Smart Storage Administrator (SSA) on a supported HPE Smart Array controller?
- A . Use the "Migrate RAID Level" function, as this is a supported online migration path.
- B . Add two new drives to the RAID 1 array and select the "Transform to RAID 10" option.
- C . Use the "Extend Logical Drive" function, as RAID 10 is an extension of RAID 1.
- D . Delete the RAID 1 logical drive (destroying all data) and create a new RAID 10 logical drive.
A Network Administrator is investigating slow file transfers to a server.
Performance Data:
– CPU Utilization: 10%
– Memory Utilization: 15%
– Network I/O: 120 MB/s (Sustained)
– Network Errors/Discards: High
Server Design:
– 1 x 1GbE Network Adapter (Single Port)
What is the performance bottleneck?
- A . The server needs more RAM.
- B . The server’s storage is too slow.
- C . The server’s CPU is the bottleneck.
- D . The 1GbE network adapter is saturated.