Practice Free NS0-593 Exam Online Questions
You have a new VMware vSphere cluster with ESXI 7.0U2 hosts. The hosts are connected to a 4-node AFF A400 NetApp ONTAP9.8 cluster with FC LUNs. You have a requirement to identify and follow I/Os from each VM on the shared FC LUN-backed datastores for troubleshooting purposes.
In this scenario, which VMware feature Is supported by ONTAP software to accomplish this task?
- A . Network I/O Control (NIOC)
- B . Virtual machine ID (VMID)
- C . Storage I/O Control (SIOC)
- D . vSphere Cluster Services (vCLS)
A 2-node cluster hosts only NAS data UFs. Allnodes lose access to the cluster network.

Referring to the exhibit, which statement is correct?
- A . Both nodes race to takeover the other, one node will takeover the other node.
- B . No takeover event will occur and NAS data UFs will not be accessible.
- C . All nodes in the cluster reset and NAS data UFs are not accessible after reboot.
- D . NAS data UFs are accessible on only the node that has Epsilon.
After expanding a two-node AFF A300 cluster with two AFF A700 nodes, you observe latencies when data is accessed indirectly. The system node run -node -command netstat command shows retransmits and packet drops on the LIFs. The AFF A700 nodes with 40 Gbps and the AFF A300 connect with 10 Gbps to the cluster interconnect. You are using Cisco Nexus 3132Q cluster interconnect switches. You just updated to ONTAP 9.8 software.
In this scenario, what is causing this problem?
- A . The 10 Gbps to 10 Gbps cluster Interconnect is creating a speed mismatch.
- B . AFF A300 and AFF A700 node mixing Isnot supported in ONTAP 9.8 software.
- C . The AFF A300 Is using an adapter card for the cluster Interconnect, but only onboard ports are supported.
- D . There is an NXOS firmware mismatch, verify in the Interoperability Matrix (1MTJ for a supportedversion.
You have a 2-node NetApp FAS2750 switchless cluster with twenty-four 1.8 TB disks that is experiencing performance issues.
Upon investigation, you discover severaltype B consistency points.

Referring to the exhibit, which corrective action would address these consistency points?
- A . Create additional data LIFs.
- B . Convert the 2-node switchless cluster to a 2-node switched cluster.
- C . Add an additional shelf oftwenty-four 1.8 TB disks.
- D . Replace the twenty-four 1.8 TB disks with twelve 4 TB disks.
A user mentions that their home drive, that Is an export within a volume, is no longer allowing them to save files. The drive reports that it Is full, even though It shows that minimal data is written to it.
Which statement would explain this behavior?
- A . The mount is stale and uses a cached version of the volume.
- B . Other users wrote to this user’s home drive.
- C . Other files within the volume are also owned by the user, exceeding the user quota.
- D . The client system needs to remount the export to show the proper space.
You receive the panic message shown in the exhibit.

In this scenario, which component should you troubleshoot first?
- A . the PCI card in slot 3
- B . the MetroCluster FC-Vl card in slot 6
- C . the memory module in slot 1
- D . the CPU
A customer reports that while Installing Windows updates on their external Vscan servers, clients couldnot access any files on their CIF-S SVM. The problem disappeared after the update process was completed. The customer wants to prevent this issue from happening during the next patch window.
In this scenario, what are two ways to accomplish this task? (Choose two.)
- A . Enable the -scan-mandatory flag in the Vscan policy.
- B . Update the Vscan servers one at a time.
- C . Modify the CIFS shares to be continuously available (CA) shares.
- D . Disable the -scan-mandatory flag in the Vscan policy.
After users start reporting the Inability to create new flies in a CIFS share, you find EMS events for wafl.dir.size.max logged for the volume of the SVM to which the share points.
In this scenario, which action should you take to solve this issue?
- A . Delete unneeded files from the directory.
- B . Move the volume to a different aggregate.
- C . Increase the maximum numberof files for the volume.
- D . Increase the maximum directory size for the volume.