Practice Free NS0-593 Exam Online Questions
You are optimizing your Cloud Volumes ONTAP. For interoperability and consolidation purposes, you need to know the storagelimits.
In this scenario, which source should be reviewed?
- A . NetApp Cloud Volumes ONTAP Release Notes
- B . Hardware Universe
- C . Interoperability Matrix Tool (IMT)
- D . Cloud Central
A customer with an FC MetroClusterconfiguration that is running NetApp ONTAP 9.8 software experienced a site outage and wants to know why the MetroClusler configuration did not switch over to the other site.
What are two reasons for this problem? (Choose two.)
- A . There was a failed PSU in the switchover site.
- B . The ISLs were down between the sites.
- C . The site had unmirrored aggregates.
- D . An ISL link was not operating at 16Gbps.
After a motherboard replacement on a NetApp AFF A300 in a SAN environment, the customer states that ports 0e and 0f are unable toconnect to the fabric. The ports report "offline".
What would you examine first to troubleshoot the issue?
- A . vserver fcp wwpn-alias show command output
- B . system node hardware unified-connect show command output
- C . storage port show command output
- D . vserver fcp interface show command output
You have a NetApp ONTAP cluster consisting of four NetApp FAS8200 controllers with two NetApp CN1610 cluster switches running ONIAP 9.8 software. You are receiving several alert messages stating that the cluster network has degraded. After troubleshooting, you determine that the errors are being generated from Node 2, interface e0b.
In this scenario, what should you do first to solve this problem?
- A . Replace the Twinax cable between Node 2, Interface e0b. and the NetApp CN1610 switch.
- B . Replace the motherboard on Node 2.
- C . Replace both NetApp CN1610 switches.
- D . Replace the NetApp CN1610 switch that connects to Node 2, interface e0b.
The motherboard of Node-01 is being replaced. To perform this task, a takeover was Initiated from Node-02. Node-02 panics showing the string below.
PANIC; Permanent errors on all HA mailbox disks (while marshalling header) in SKprocess fnmbx_instanceWorker on release 9.5P8 (C)
What has happened in this situation?
- A . While in maintenance mode, the sldiag device show command was executed.
- B . While in maintenance mode, the fcadmin device_map command was executed.
- C . While in maintenance mode, the HA_config show command was executed.
- D . While in maintenance mode, the mailbox destroy local command was executed.
When an administrator tries to create a share for an existing volume named voll, the process fails with an error.

Referring to the exhibit, what Is the reason for the error?
- A . The volume must have a type of DP.
- B . The volume has not beenmounted.
- C . The CIFS service is not authenticating properly with the domain controller.
- D . The CIFS service is not in workgroup mode.
Recently, a CIFS SVM was deployed and is working. The customer wants to use the Dynamic DNS(DDNS) capability available in NetApp ONTAP to easily advertise both data UFs to their clients. Currently. DNS is only responding with one data LIF. DDNS is enabled on the domain controllers.

Referring to the exhibit, which two actions should be performed to enable DDNS updates to work? (Choose two.)
- A . Disable the -vserver-fqdn parameter for the SVM DDNS services.
- B . Remove the NFS protocol from the cifs_01 data LIF.
- C . Enable the -use-secure parameter for the SVM DDNS services.
- D . Enable the -is-enabledparameter for the SVM DDNS services
A customer reports that some of their client computers are unable to access a FlexGroup over CIFS. This problem involves only their older Windows XP clients and some printers and scanners.
In this scenario, which statement Is correct?
- A . FlexGroup requires CIFS shares to be located in qtrees, which these clients do not support.
- B . FlexGroup requires CIFS shares to use the Continuously Available Feature, which these clients do not support.
- C . These systems use the SMQI protocol which Is an unsupported feature in FlexGroup
- D . These systems use Offloaded Data Transfer, which is an unsupported feature in FlexGroup.
You are troubleshooting a CIFS connection issue that is reported by some users. You decide to collect a packet trace.
In this scenario, after you generate the packet trace, where do you find the trace file?
- A . /packet_traces of the node hosting the LIF
- B . /etc/log/packet_traces of the node hosting the LIF
- C . /etc/log/mlog/packet._traces Of all nodes
- D . /vol0/paclcet_traces of the CIFS SVM
Your customer has mounted an NFS SVM from a Linux client unci performance is very poor. The customer is certain that they have jumbo frames enabled. They have verified an MTU of 9000 on both the Linux client and the broadcast domain on the NetApp ONTAP 9.8 cluster.

Referring to the exhibit, which ONTAP command will help isolate a possible MTU mismatch?
A)
![]()
B)
![]()
C)
![]()
D)
![]()
- A . Option A
- B . Option B
- C . Option C
- D . Option D