Practice Free D-PE-OE-23 Exam Online Questions
A technician receives a new server with five drives.
They need to configure the drives based on the following requirements received from the administrator:
– Drive 0 as a single disk with no RAID
– Drives 1-3 as a RAID 5 with drive 4 as a hot spare just for this newly created RAID 5
The administrator plans to add more disks as separate RAID arrays at a later date but only wants drive 4 to be available for this first RAID 5 set.
How should the technician configure the drives?
- A . Set drive 0 to Ready; set drives 1-3 as RAID 5; set drive 4 as a Global Hot Spare
- B . Set drive 0 to Non-Raid; set drives 1-3 as RAID 5; set drive 4 as a Dedicated Hot Spare
- C . Set drive 0 to Non-Raid; set drives 1-3 as RAID 5; set drive 4 as a Global Hot Spare
- D . Set drive 0 to Ready; set drives 1-3 as RAID 5; set drive 4 as a Dedicated Hot Spare
A technician needs to repurpose a Dell EMC PowerEdge server. The server has dual processors with 18 cores each The OS only "sees" 24 threads in total.
Which setting should the technician change in Processor Settings in the System BIOS?
- A . System Profile
- B . Virtualization Technology
- C . HyperThreading
- D . Number of Cores per Processor
A technician is setting up SNMP Trap Alerts on a 14G servers.
After specifying the trap destination address, what should be the next step?
- A . Enable the SMNP Client service on the iDRAC
- B . Include the server OS IP address in the destination systems authentication script
- C . Enable the SMNP services in the server operating system of the sending server
- D . Send an SNMP trap test to the destination system
What is a key feature of Part Replacement in Lifecycle Controller?
- A . What is a key feature of Part Replacement in Lifecycle Controller?
- B . Automatically updates the configuration of the new part.
- C . Automatically updates the server configuration database.
- D . Runs a parts replacement wizard.
Which operation should a technician perform to ensure configuration recovery if a server must be physically replaced?
- A . View and export the current hardware inventory
- B . Create and export a Server Configuration Profile
- C . Back up and export the Server Profile to a network share
- D . Back up the Server Profile to vFlash
iDRAC9 System Lockdown Mode is enabled.
In addition to the Power cap setting and System power operations, which settings can an administrator access?
- A . Update firmware
Diagnostics - B . Update firmware
Lifecycle Controller - C . Part replacement
Lifecycle Controller - D . Part replacement
Diagnostics
A technician creates two virtual disks and assigns a dedicated hot spare to each virtual disk. The technician also creates a global hot spare. A drive fails on the second virtual disk.
What is the result?
- A . The dedicated hot spare for the virtual disk replaces the failed drive.
- B . The global hot spare replaces the failed drive.
- C . A copyback operation occurs between the failed drive and the dedicated hot spare.
- D . A copyback operation occurs between the failed drive and the global hot spare.
The operating system on a Dell PowerEdge R760xa fails to boot.
What iDRAC feature under the iDRAC UI Troubleshooting tab can be used to diagnose the issue?
- A . System Event Logs
- B . POST code state
- C . SupportAssist collection
- D . Post package repair
A technician needs to set a server to always attempt PXE boot before booting to the hard drive.
What two items does the technician need to set to achieve this? (Choose two.)
- A . Remove all boot options except network card
- B . Select PXE Boot from F11 Boot Manager
- C . Change the Boot Sequence so the network card is first
- D . Set the Legacy Boot Protocol for the network card to PXE
A technician replaces a faulty system board on a server. In addition to powering on the system, what step must the technician take to install the correct service tag?
- A . Type asset <asset tag> to change the asset tag
- B . Login in to the iDRAC
- C . Press F11 to start the Boot Manager
- D . When prompted by Easy Restore, press Y to restore the Service Tag, license, and diagnostics information