Practice Free D-PE-OE-23 Exam Online Questions
A technician sets up Automatic Updates via the iDRAC GUI to schedule updates for 9pm that day. The next morning, the technician notices that the updates were NOT applied.
What configuration change will allow this process to be automated?
- A . Change the time in Update Window Schedule
- B . Enable the Delayed Automatic Reboot option
- C . Select Schedule Updates and Reboot Server
- D . Modify Recurrence Pattern to Weekly
A technician tries to power on a server but nothing happens when they press the power button. The status LEDs on both PSUs are green. The technician is able to connect to the iDRAC to review the System Event Logs and discovers that PSU2 has failed.
- A . Reboot the server
Reset the NVRAM - B . Reboot the server
Test one PSU at a time - C . Cycle the AC power
Test one PSU at a time - D . Cycle the AC power
Reset the NVRAM
The administrator plans to deploy secure connect gateway in the environment. The environment consists of Windows, Linux, and VMware.
Where should the application be installed?
- A . Can deploy a system running OS X and install on the system
- B . Must implement as system running a Windows OS and install on the system
- C . Must be installed on a PowerEdge server running iDRAC9
- D . Can be installed on a virtual machine running the Linux OS
A technician receives a repurposed PowerEdge server. After racking and cabling the server, they attempt to log into the iDRAC but cannot do so. The default login account has been disabled.
What method can be used to enable the default login account?
- A . Run the racadm racreset command from the host OS
- B . Boot to F2 and select iDRAC Settings > Reset iDRAC configurations to defaults all
- C . Hold down the i button for 16 seconds
- D . SSH into the iDRAC and run the racadm racreset command
A technician recently installed a supported third-party PCIe expansion card and updated the iDRAC firmware on a server. The server is now experiencing internal temperatures that are higher than normal. A second technician is troubleshooting the server and discovers that the expansion card is hot to the touch.
What should the technician do to resolve this issue?
- A . Adjust the Multi Vector Cooling values.
- B . Adjust the power settings.
- C . Reseat all the fans.
- D . Replace the fans one at a time until the faulty fan is identified.
A technician is attempting to install a 64-bit OS on a server. The OS array is 2.8 TB. The OS install is unable to see the disk.
What should the technician do to install the OS?
- A . Switch the boot settings to UEFI
- B . Use USB to load Storage Drivers
- C . Use LC to install the OS
- D . Switch the Hard Drive boot sequence so that C: is first
Which two iDRAC license editions support enabling the Lockdown Mode feature? (Select 2)
- A . iDRAC Basic
- B . iDRAC Datacenter
- C . iDRAC Express
- D . iDRAC Enterprise
Which export type in iDRAC restores a Server Configuration Profile to a known baseline?
- A . Advanced
- B . Replacement
- C . Basic
- D . Clone
A technician needs to repurpose a server. The server has dual processors with 18 cores each. The OS only sees 24 threads in total.
Which setting should the technician change in Processor Settings in the System BIOS?
- A . Number of Cores per Processor
- B . System profile
- C . Virtualization Technology
- D . Hyperthreading
Which component of the Dell EMC PowerEdge server provides system information, status, and error messages to indicate when the system is operating correctly, or when the system needs attention?
- A . RACADM
- B . Front Panel LCD
- C . BIOS
- D . UEFI