Practice Free D-PE-OE-01 Exam Online Questions
A technician is using the default installation of iSM.
Where can they find the replicated LC logs using the Windows Event Viewer?
- A . Application
- B . Forwarded Events
- C . Security
- D . System
A system administrator, while working with tech support, is asked to check the blinking LEDs on the Dell PowerEdge 16G server.
Where should the administrator look?
- A . On the right control panel
- B . On the system board
- C . On the left control panel
- D . On the front LCD panel
A technician updates firmware on all server components. After the updates have completed, testing of the NIC reveals a possible firmware problem.
What should the technician do to return the NIC to service?
- A . Replace the NIC using Part Replacement
- B . Import the most recent Server Profile
- C . Perform Firmware Rollback
- D . Enable Collect System Inventory on Restart
A technician needs to install several firmware updates on a server. The server cannot be rebooted until the customer performs a routine reboot.
What method should the technician use?
- A . Upload all the firmware revisions using the Lifecycle Controller and then click Install Next Reboot.
- B . Upload all the firmware revisions using the iDRAC and then select install Non-Reboot Only
- C . Compress all the firmware revisions into a zipped file then use the iDRAC to upload and select Install Next Reboot
- D . Upload all the firmware revisions using the iDRAC and then click Install Next Reboot.
A technician is remotely installing ESXi 6.0 on a PowerEdge R640 in BIOS boot mode. The system has dual internal SD cards. After the OS is installed, the system reboots and shows an error screen with the following message: “No boot device found”
What should the technician do to resolve this issue?
- A . Enable vFlash in iDRAC web GUI
- B . Set the boot made from BIOS to UEFI
- C . Reseat the SD cards and try to boot to them again
- D . Change the Hard Disk Drive Sequence
You have been tasked with configuring a Dell EMC PowerEdge server to be a file server. The server operating system has been installed and there are 8 x 1TB drives that must be configured.
Which RAID configuration would provide the maximum usable space with maximum redundancy?
- A . RAID 10
- B . RAID 5
- C . RAID 50
- D . RAID 0
Which component of the Dell EMC PowerEdge 13G server can be used as an indicator to locate a specific system within a rack?
- A . iDRAC8
- B . Back Panel
- C . LCD Front Panel
- D . System ID button
A technician needs to perform a RAID controller firmware update from within the Operating System. The server runs Red Hat Enterprise Linux and is configured with an iDRAC basic license.
Which three steps should the technician take to complete this task? (Choose three.)
- A . R estart the server and press F10 t o start the firmware update process
- B . After firmware update, run fsck command on the virtual disks
- C . Obtain the latest firmware update for the RAID controller
- D . Run racadm fwupdate command from a management station
- E . Open a command shell and execute the firmware package
- F . After the firmware update, restart the server
A technician needs to perform a RAID controller firmware update from within the Operating System. The server runs Red Hat Enterprise Linux and is configured with an iDRAC basic license.
Which three steps should the technician take to complete this task? (Choose three.)
- A . R estart the server and press F10 t o start the firmware update process
- B . After firmware update, run fsck command on the virtual disks
- C . Obtain the latest firmware update for the RAID controller
- D . Run racadm fwupdate command from a management station
- E . Open a command shell and execute the firmware package
- F . After the firmware update, restart the server
A technician wants to install a new version of OMSA onto a server that already has an existing version of OMSA.
What is required for this new installation?
- A . iSM must also be installed on the managed server
- B . iDRAC firmware needs to be at version 5.0 or higher
- C . Existing OMSA version must be disabled in Services
- D . Existing OMSA must be uninstalled before the new version is installed