Practice Free D-PE-OE-01 Exam Online Questions
Case Study 3
A financial services company has file sharing workflows and 2000 home directories which include 70% Microsoft Windows and 30% Linux. The Security team is also interested in credit card usage data analytics such as point of sale, geolocation, and authorization and transaction data. Home directories and file shares do not require D@RE or SEC compliance.
However, due to the sensitivity of the credit card data, the company requires D@RE for credit card information and must adhere to the U.S. SEC 17a-4(f) compliance standards. Additionally, they are interested in auditing user access and anti-virus features.
The compute and storage environment consists of the following:
– 200 TB of Fibre Channel drives on NetApp ONTAP 7
– Environment is expected to grow 200 TB over the next three years
Which combined solution addresses the company’s requirement for D@RE and U.S.SEC 17a-4(f)?
- A . All Flash and SmartLock Compliance mode
- B . SmartLock Enterprise mode and STIG
- C . SED and SmartLock Enterprise mode
- D . SED and SmartLock Compliance mode
Which LED status indicates that System ID mode is active in a Dell PowerEdge R760 server?
- A . Solid blue
- B . Blinking blue
- C . Solid white
- D . Blinking amber
A system administrator is trying to connect to iDRAC Direct. At what port blink frequency is the USB port activity confirmed?
- A . Two per second
- B . One per second
- C . Eight per second
- D . Four per second
Case Study 4
A company is experiencing a noticeable decrease in performance when accessing data purpose file shares. In addition, a file pool policy moves data that has not been modified for the slow data access.
The number of users accessing the cluster has not changed. The administrator has shared the following baseline metrics. The outputs were captured from a performance-acceptable time frame.
Trace route shows:
– 3 hops between clients and the cluster
– Average latency is 3 ms
Iperf shows:
– 940 Mb/s average bandwidth
– 005 ms average jitter
Netstat on the local network shows:
– 05% average re-transmission rate
Hostcache list:
– 20 ms average roundtrip time across all clients
The administrator shows you the following output from the netstat command:
– 32366653 data packets (35556615947 bytes)
– 8010 data packets (9525723 bytes) re-transmitted
Based on the output, what information should be provided to the administrator?
- A . Re-transmission rates have no impact on performance
- B . Re-transmission rate exceeds recommendations
- C . Re-transmission rate is in the acceptable range
- D . Change in the re-transmission rate indicates an issue
A technician is setting up SNMP Trap Alerts on a 14G servers.
After specifying the trap destination address, what should be the next step?
- A . Enable the SMNP Client service on the iDRAC
- B . Include the server OS IP address in the destination systems authentication script
- C . Enable the SMNP services in the server operating system of the sending server
- D . Send an SNMP trap test to the destination system
Click the Launch Simulator button.
Using the iDRAC UI, what is listed as the Cache Memory Size for the H965i storage controller?
Note: It is necessary to close (x) the simulator window before you can select a response to this question.

- A . 965 MB
- B . 8361 MB
- C . 1064 MB
- D . 8GB
D
Explanation:
Launch the Simulator:
Open the PowerEdge iDRAC simulator to access the user interface and perform the required task.
Navigate to System Information:
In the top menu bar, select the "Configuration" tab.
From the options that appear, choose "Storage". This section will display details and configurations
for the storage controllers installed on the server.
Check the H965i Storage Controller:
Locate the H965i storage controller in the list. Selecting it should bring up a summary page with various specifications for the controller.
Look for the field labeled "Cache Memory Size". This will provide the cache memory size value for the controller.
A PowerEdge R740 server has a BOSS subsystem installed with two SSDs. A technician needs to configure the SSDs as a RAID 0 virtual disk and then load the operating system onto the BOSS SSDs.
However, the technician is unable to create the RAID 0 virtual disk.
What is the issue?
- A . The operating system can only be installed on a RAID 0 virtual disk
- B . BOSS does not support RAID 0
- C . The operating system cannot be installed on a BOSS subsystem SSD
- D . BOSS only supports RAID 0 on a single SSD
A PowerEdge R740 server has a BOSS subsystem installed with two SSDs. A technician needs to configure the SSDs as a RAID 0 virtual disk and then load the operating system onto the BOSS SSDs.
However, the technician is unable to create the RAID 0 virtual disk.
What is the issue?
- A . The operating system can only be installed on a RAID 0 virtual disk
- B . BOSS does not support RAID 0
- C . The operating system cannot be installed on a BOSS subsystem SSD
- D . BOSS only supports RAID 0 on a single SSD
A technician needs to repurpose a server.
What should they do to prepare the server for its new role?
- A . Boot into F10, select System Erase, and press ‘Y° to confirm erase
- B . Enable Delete All Settings in the iDRAC Troubleshooting section
- C . Boot into F10, navigate to Retire or Repurpose Server, and Select Components to be cleared
- D . Boot to Ctrl+S and perform Network Erase
What is the difference between iDRAC Direct 2.0 in 14G and iDRAC Direct in 13G Dell EMC PowerEdge servers?
- A . Support on rack servers
- B . Sharing of iDRAC Direct port with OS
- C . Availability on certain low-end servers
- D . Speed of the connection
