Practice Free D-PE-OE-01 Exam Online Questions
What is the recommended option to use when applying firmware to a replaced part using the Lifecycle Controller?
- A . Disabled
- B . Allow version upgrade only
- C . Match firmware of replaced part
- D . Upgrade to latest available version
A technician creates two virtual disks, Vdisk1 and Vdisk2, and assigns a dedicated hot spare for Vdisk1. A drive fails on Vdisk2.
What is the result?
- A . Rebuild operation occurs in Vdisk2.
- B . Dedicated hot spare replaces the failed disk.
- C . Vdisk2 loses one remaining redundancy.
- D . RLM runs for the failed disk.
A company has an existing Dell EMC 4-node X410 Gen 5 cluster with approximately 100TB of SMB shares connected using two InfiniBand 8-port switches.
The company wants a technical refresh of the cluster with a new 4-node H500 Gen 6 cluster with two 16-port InfiniBand switches. The existing cluster has SyncIQ, SmartConnect Advanced, and SmartPools licenses installed.
To move the data from the existing modes to the new nodes, which migration plan is recommended?
- A . Setup a new cluster with the new Gen 6 nodes and its InfiniBand switches Use SyncIQ to migrate the data and then SmartFail the existing cluster
- B . Setup a new cluster with the new Gen 6 nodes and its InfiniBand switches Use EMCopy to migrate the data and then use “sharedup” to create the shares
- C . Modify the default file pool policy to move the data Swap the existing InfiniBand switches with the new switches
- D . Add the new nodes to the existing cluster Modify the default file pool policy to move the data and then SmartFail the existing nodes
A company has an existing Dell EMC 4-node X410 Gen 5 cluster with approximately 100TB of SMB shares connected using two InfiniBand 8-port switches.
The company wants a technical refresh of the cluster with a new 4-node H500 Gen 6 cluster with two 16-port InfiniBand switches. The existing cluster has SyncIQ, SmartConnect Advanced, and SmartPools licenses installed.
To move the data from the existing modes to the new nodes, which migration plan is recommended?
- A . Setup a new cluster with the new Gen 6 nodes and its InfiniBand switches Use SyncIQ to migrate the data and then SmartFail the existing cluster
- B . Setup a new cluster with the new Gen 6 nodes and its InfiniBand switches Use EMCopy to migrate the data and then use “sharedup” to create the shares
- C . Modify the default file pool policy to move the data Swap the existing InfiniBand switches with the new switches
- D . Add the new nodes to the existing cluster Modify the default file pool policy to move the data and then SmartFail the existing nodes
You are creating a new RAID 5 storage pool on a Dell EMC PowerEdge server based on 30 x 1TB drives.
Which PERC model best supports this configuration?
- A . S140
- B . H740P
- C . H740T
- D . H330
A technician is sent on-site to troubleshoot a server that reports errors during POST when rebooted. The LCD is amber. The error message is as shown: correctable memory error rate exceeded for DIMM B4 The server has a limited maintenance window. The technician needs to troubleshoot efficiently.
Which step should the technician take to troubleshoot?
- A . Reseat all memory
- B . Swap DIMM B4 with A4
- C . Swap DIMM B4 with B2
- D . Replace DIMM B4
An engineer needs to install an additional PSU on an existing, single PSU Dell EMC PowerEdge R740. They complete the initial installation and cabling procedures. They connect an AC cable and the power distribution unit produces normal AC output. The engineer checks power management and sees that the new PSU is in the Failed state.
What task should be completed to troubleshoot this issue?
- A . Confirm the System Input Power CAP is not set to Low
- B . Set the PSU AC redundancy to 1+1
- C . Set the PSU AC redundancy to 1+0
- D . Verify the new PSU is the same type and wattage rating
What is the default location of the extracted files of the OMSA installer?
- A . C:Program FilesSystem32
- B . C:OpenManage
- C . C:WindowsTemp
- D . Current directory
A technician deploys a server. The iDRAC was configured with a static IP address and hostname. The technician is not able to ping the iDRAC from the workstation when using the hostname. However, they can ping the iDRAC with the IP address.
Which setting should the technician configure to address the issue?
- A . DNS Name in the Lifecycle Controller
- B . Register DRAC on DNS option in the iDRAC GUI
- C . DNS Server value in the Lifecycle Controller
- D . Reset DNS Cache option in the IDRAC GUI
What is required to use the Quick Sync 2 feature?
- A . OpenManage Mobile app
- B . Type A/A USB cable
- C . NFC
- D . Ethernet connection to iDRAC NIC