Practice Free D-PE-OE-01 Exam Online Questions
Your customer requires a way to monitor a high-level and holistic view of the workload of their servers. A database server was identified as providing lower than expected performance after migrating to a PowerEdge R760 server.
Which option can be selected in iDRAC to monitor this level of information?
- A . CPU Utilization
- B . I/O Utilization
- C . Memory Utilization
- D . System Level CUPS Index
Your company is decommissioning a PowerEdge 16G server to a 17G server. All the disks in the 16G server are SEDs. Your security team requires that the server is securely retired.
Which feature can be used to comply with the security requirement?
- A . Use LifeCycle Controller ISE feature
- B . Enable Secure Boot in BIOS
- C . Enable Lockdown Mode in iDRAC
- D . Use SCV application feature
After updating BIOS and NIC firmware using Lifecycle Controller, a PowerEdge server boots into Lifecycle Controller instead of the OS, although the OS disks are intact.
What is the most likely root cause?
- A . Boot mode was changed
- B . RAID metadata corruption
- C . Secure Boot certificates expired
- D . iDRAC lost network connectivity
During a physical Inspection, the System Status LED Is blinking blue.
What does this indicate?
- A . Hardware fault detected
- B . PSU redundancy lost
- C . Thermal threshold exceeded
- D . System is being identified
A technician In Portland, Oregon has been asked to update the firmware on a server in Omaha, Nebraska. They will use an NFS server also located in Nebraska for serving patches that have been vetted by their security teams.
What two pieces of information does the technician need in order to access the NFS patch server from the Lifecycle Controller or iDRAC?
- A . Client IP address
- B . CHAP authentication credentials
- C . Share name
- D . Username and password
An administrator wants to ensure continuous visibility into the hardware health of a Dell PowerEdge server and be notified immediately if a component begins to fail.
Using iDRAC, what action should be taken to meet these requirements?
- A . Monitor hardware health only through the operating system tools
- B . Log in to iDRAC only after the operating system reports a failure
- C . Configure iDRAC hardware health monitoring with automated alerting
- D . Disable system alerts to reduce unnecessary notifications
You plan to update several components (PERC, NIC, BIOS) on a PowerEdge R760. The customer requires a rollback option if compatibility Issues appear.
Which two actions should you take to prepare for a rollback?
- A . Record all currently installed firmware versions
- B . Rely on automatic hardware rollback built into all PowerEdge models
- C . Validate that rollback is supported for the component being updated
- D . Download previous firmware versions beforehand
A PowerEdge R750 reports “Degraded" status with a question mark next to several components in iDRAC, but all OS-level monitoring tools show no hardware errors.
What should be checked first to identify the cause?
- A . System Event Log (SEL)
- B . BIOS boot mode
- C . Lifecycle Controller firmware version
- D . RAID virtual disk layout
You are replacing a network card in a Dell server. The new card has a firmware version lower than the existing part. The Lifecycle Controller Is set to Allow Version Upgrade only under the Part Firmware Update setting.
What will happen to the firmware after replacing the card?
- A . Forces downgrade of existing firmware
- B . Updates the network card firmware
- C . Prevents all firmware updates
You are assisting an administrator, who Is working on a PowerEdge R670. They are trying to connect to iDRAC using iDRAC Direct but cannot make a connection. The LED status indicators are: the wrench/spanner LED on the front right is off, the system ID LED on the front right is blinking blue, and the power LED on the front right is amber.
What action should be taken to establish connectivity?
- A . Press the power button once
- B . Press and hold the system ID button for 5-10 seconds
- C . Press the system ID button once
- D . Press and hold the power button for 5-10 seconds