Practice Free HPE0-S59 Exam Online Questions
You plan to configure a Link Aggregation Group (LAG) for two connections within a server profile for a compute node running an ESXI system.
What is required from the VMware side to enable LAG?
- A . Virtual Distributed Switch
- B . vSphere Standard license
- C . Load balancing cluster
- D . Dedicated VMKernel port
A
Explanation:
To configure a Link Aggregation Group (LAG) for two connections within a server profile for a compute node running an ESXi system, a Virtual Distributed Switch (VDS) is required from the VMware side. VDS allows for the configuration of LAGs and provides advanced network features such as centralized management and monitoring, which are essential for setting up and managing LAGs.
Reference: VMware vSphere Networking Guide
Your customer plans to deploy ESXi systems to HPE Synergy and HPE ProLiant servers using HPE OneView for VMware vCenter Server.
Which statement about HPE OneView for VMware vCenter Server functionality is true for this environment?
- A . HPE ProLiant servers need an HPE OneView for VMware vCenter Server license for full functionality
- B . Individual systems can be added to HPE OneView for VMware vCenter Server through an ILO management processor
- C . HPE Synergy requires HPE Composer 2 for full functionality of HPE OneView for VMware vCenter Server
- D . Only systems managed using HPE Oneview can use HPE Oneview for VMware vCenter Server functionalities
DRAG DROP
Your customer wants to update the firmware for 36 HPE Synergy 480 Gen 10 compute modules with a server profile assigned from a server profile template.
Put the steps required to achieve this goal on the left into their correct order on the right.

Explanation:
To update the firmware for the HPE Synergy 480 Gen 10 compute modules with a server profile assigned from a server profile template, the steps should be performed in the following order:
Upload SPP to HPE OneView repository.
(First, the Service Pack for ProLiant (SPP) containing the firmware updates must be uploaded to the HPE OneView repository.)
Select Firmware baseline within server profile template.
(Next, you need to select the desired firmware baseline in the server profile template.)
Select installation method (online or offline).
(Choose whether the firmware updates will be installed online or offline.)
Update all server profiles from the template.
(Finally, update all server profiles from the modified template to apply the firmware updates to the compute modules.)
Your customer experienced some problems caused by outdated HPE Superdome Flex firmware.
Which update method should they use to avoid these issues in the future?
- A . HPE OneView method for I/O firmware update procedure
- B . RMC CLI to update I/O and HPE Persistent Memory firmware
- C . HPE OneView IT HPE Persistent Memory firmware must be updated.
- D . HPE SUM if HPE Persistent Memory firmware must be updated
D
Explanation:
HPE System Update Manager (SUM) is the recommended method for updating firmware on HPE Superdome Flex systems, especially when HPE Persistent Memory firmware needs to be updated. HPE SUM ensures that all firmware components are updated correctly and consistently, reducing the risk of compatibility issues.
Reference: HPE Superdome Flex Firmware Update Guide
DRAG DROP
After HPE Superdome Flex deployment and nPar setup, you need to verify health status of HPE Superdome Flex components.
Put the steps on the left into the coned order on the right to perform this task.

Explanation:
Open SSH client: Begin by opening an SSH client on your computer. This client will be used to establish a secure connection to the Rack Management Controller (RMC).
Open session to RMC: Use the SSH client to open a session to the RMC. The RMC is the central management component for the HPE Superdome Flex system.
Enter show health command: Once connected to the RMC, enter the show health command. This command will provide detailed information about the health status of various components within the Superdome Flex system.
Confirm health status: Review the output of the show health command to confirm the health status of the Superdome Flex components. This step ensures that all components are functioning correctly and identifies any potential issues.
Reference: HPE Superdome Flex Management Guide
Your customer is trying to grow a VMware duster using HPE OneView for VMware vCenter Server. They get an error and cannot proceed
Which tool should you use to troubleshoot the problem?
- A . HPE One View for VMware vCenter Server to verify if server profile template s property imported and registered
- B . vCenter Server to verify if an OS Bund Plans property defined and has ESXi image uploaded
- C . HPE OneView interface to import an existing cluster using the hypervisor cluster profile functionality.
- D . ILO interlace of a given HPE Synergy compute node to verify whether this node is registered within HPE Oneview.
A
Explanation:
When encountering an error while growing a VMware cluster using HPE OneView for VMware vCenter Server, it is crucial to verify that the server profile template is properly imported and registered in HPE OneView. This ensures that the necessary configurations and settings are correctly applied to the new compute nodes being added to the cluster.
Reference: HPE OneView for VMware vCenter Server User Guide
Your customer wants to add a second HPE Synergy frame to an existing logical enclosure Based on a single HPE Synergy frame. The customer wants to use a highly available master setup.
Which procedures should De performed during the expansion process? (Select two.)
- A . Create a new logical interconnect group and enclosure group for two frames setup
- B . Create a new logical enclosure based on both HPE Synergy frames.
- C . Re-parent an existing enclosure group to the new logical interconnect group.
- D . Modify an existing logical interconnect to include second HPE Synergy frame.
- E . Move one of the master modules to the appropriate interconnect bay in the second frame.
DE
Explanation:
To expand an existing logical enclosure based on a single HPE Synergy frame to include a second frame and ensure a highly available master setup, the following steps should be performed:
Modify an existing logical interconnect to include the second HPE Synergy frame: This step involves updating the logical interconnect configuration to encompass the new frame, ensuring network connectivity and consistency across both frames.
Move one of the master modules to the appropriate interconnect bay in the second frame: To achieve a highly available master setup, one of the master modules should be relocated to the second frame, providing redundancy and high availability for the management components.
Reference: HPE Synergy Frame Expansion Guide
Your customer manages HPE Synergy using HPE OneView. For one of its projects, the company purchased 50 HPE.
ProLiant DK385 Gen10 Plus v2. They plan to manage the new systems using HPE OneView as well.
What should the customer do to manage rack system using HPE OneView?
- A . add the rack system to the HPE OneView instance used to manage HPE Synergy to centralize management of all systems.
- B . connect the rack system to an IPDU and add the IPDU to the HPE. OneView instance that is used for HPE synergy management.
- C . Deploy HPE OneView Global Dashboard and add the rack systems there, as AMD systems are not directly in HPE OneView.
- D . Deploy an HPE OneView virtual appliance, and, after configuration, use it to manage only the rack
systems.
A
Explanation:
HPE OneView can manage both Synergy and ProLiant systems, allowing for centralized management of all infrastructure components. By adding the HPE ProLiant DL385 Gen10 Plus v2 systems to the existing HPE OneView instance used for Synergy, the customer can streamline management processes and maintain a unified management interface for all systems.
Reference: HPE OneView User Guide
HOTSPOT
Click the option that will allow you to create an OS Deployment Plan with customized kickstart.

Your customer has me following HPE Synergy setup
– Three frames fully populated with HPE Synergy 480 Gen10 Plus modules and 25Gb/s downlink speed formulating a single logical enclosure
– Two HPE Virtual Connect SE 100Gb F32 Module for Synergy
– Four HPE Synergy 50Gb interconnect Link Module
– Six HPE Synergy Virtual Connect SE 32Gb FC Modules
The customer needs to add a frame.
Which statement about the expansion of this setup is true?
- A . The additional frame must have HPE Virtual Connect FC modules installed
- B . The customer can grow the existing logical enclosure up to 5 frames
- C . The customer has to create a new logical enclosure for the additional frame
- D . The additional frame cannot have 12Gb SAS connection modules installed
B
Explanation:
HPE Synergy allows scaling of logical enclosures up to 5 frames. Given the current setup of three frames fully populated with HPE Synergy 480 Gen10 Plus modules and other specified components, the customer can add another frame to the existing logical enclosure. This flexibility in scaling ensures that the logical enclosure can be expanded without the need to create a new logical enclosure, provided that the necessary interconnect modules are in place.
Reference: HPE Synergy Planning Guide